Engineering smart zoning and thermostat setup for Silver Lake homes in CEC Climate Zone 9
Smart Zoning and Thermostat Setup planned by Breathe LA 365 in Silver Lake starts with one question: what is the room outcome the homeowner is actually buying? Once that is named, the equipment, the static pressure budget, the AHRI match, and the permit path follow. More stable occupied-room comfort without forcing one hallway thermostat to represent the whole home is the deliverable, not a brand name.
Engineering anchors for this scope: Title 24 §110.12 / OpenADR 2.0b: Wi-Fi thermostats supporting CA Title 24 demand response can receive utility load-shed signals and offset cooling setpoint up to 4°F; ACCA Manual Zr per-zone CFM minimum: each zone must receive ≥30% of system nominal CFM when calling, or pair with bypass / inverter; zone duct sizing follows Manual D for zone Manual J load; Zone-by-zone supply CFM verification at full call vs. partial calls to validate damper authority and bypass behavior.
Average summer high near 85°F with winter low around 48°F at an elevation of 485 ft and roughly 13 miles inland. CEC Climate Zone 9. The cooling design temperature for Manual J calculations runs about 94°F, with typical Manual J load landing in the 380-500 sq ft per ton band. Every audit produces a written report Marcus signs.